Empresas › Sencure B.V.

Sencure B.V.

🇳🇱 Roden, Netherlands · Hall 12 / D54 · Participante en pabellón · MEDICA 2026
Manufacturer

Contacto

🌐 https://www.sencure.com
✉️ benjamin.dejonge@sencure.com
📞 +31 85 2464950
1e, Energieweg 13, 9301LK, Roden

Stands

376 m²1 stand(s) · cuota prorrateada 8,6 m²
Hall 12 / D54

Relaciones

Expositor principal: Wearable Technologies AG

Descripción

Sencure is a semiconductor company specializing in the development of advanced analog front-ends (AFEs) for bio-potential measurements such as EEG, EMG, and ECG. Its flagship product, the SNCE800 series, is a low-power, high-performance 24-bit AFE optimized for use in wearable devices.


The integrated circuit (IC) features eight channels, each equipped with a highly sensitive analog front-end and a dedicated analog-to-digital converter (ADC). The front-end is optimized for use with both dry electrodes and conventional gel-based electrodes. With a total power consumption of less than 3 mW when all channels are active, the SNCE800 significantly reduces overall device size.


The SNCE800 was designed to simplify compliance with IEC60601-1 requirements for leakage currents, without introducing excessive noise into the system.


With its low noise, high common-mode rejection ratio (CMRR), high input impedance, and low input leakage current, the SNCE800 represents a state-of-the-art AFE—ideal for next-generation wearable remote monitoring solutions.

Stands y superficie

StandHallSuperficieDimensionesMétodoConfianzaComparten
D54Hall 12376 m²
geom. bruta 367,7
16 × 23,5 mrectangle_grid_snapped(hall_calibrated)🟢 alta44
Ubicación en Hall 12 (en rojo):
A09 · 36 m²A09C54 · 54 m²C54A35 · 20 m²C36 · 60 m²C36A31 · 21 m²D54 · 376 m²D54A48 · 36 m²A48A36 · 64 m²A36A41 · 25 m²C43 · 21 m²D63 · 20 m²A55 · 24 m²D39 · 35 m²D39D49 · 16 m²D48 · 48 m²D48B64 · 100 m²B64D75 · 15 m²C72 · 28 m²C72B71 · 16 m²C76 · 24 m²B54 · 28 m²B54A44 · 49 m²A44B75 · 16 m²C50 · 24 m²C40 · 28 m²C40A66 · 54 m²A66D45 · 20 m²C75 · 25 m²A64 · 27 m²A64A47 · 25 m²E62 · 12 m²A72 · 45 m²A72B72 · 50 m²B72C66 · 25 m²B50 · 24 m²B53 · 35 m²B53C46 · 30 m²C46F63 · 12 m²B58 · 16 m²A79 · 12 m²B47 · 20 m²D44 · 40 m²D44A54 · 60 m²A54B43 · 12 m²C57 · 12 m²B45 · 12 m²A13 · 12 m²B35 · 70 m²B35A51 · 16 m²B59 · 15 m²A71 · 36 m²A71C64 · 20 m²D34 · 80 m²D34F65 · 12 m²D76 · 24 m²E54 · 12 m²A18 · 1428 m²A18F29 · 126 m²F29A02 · 570 m²A02D02 · 285 m²D02E36 · 500 m²E36D72 · 18 m²A39 · 12 m²A78 · 35 m²A78E72 · 585 m²E72G72 · 110 m²G72A85 · 15 m²B78 · 64 m²B78B79 · 18 m²C78 · 38,5 m²C78D78 · 48 m²D78B85 · 20 m²E58 · 12 m²E66 · 12 m²A21 · 60 m²A21E02 · 120 m²E02B44 · 21 m²G57 · 72 m²G57F55 · 12 m²F57 · 12 m²F54 · 120 m²F54F02 · 103,8 m²F02B76 · 25 m²D65 · 15 m²

Capturas de la fuente

Plano interactivo oficial (stand resaltado) · 2026-11-15 11:59 UTC · abrir fuente ↗

Personas de contacto (2)

Neset Tamer
Sales Manager
Benjamin de Jonge
Product Marketing Manager

Categorías

02.04 · Wearables

Productos (2)

Documentos y vídeos

🎬 Sencure advanced biopotential AFEs bring medical devices to the next level
Linaje y fuentes (6 respuestas originales · 1 capturas)
ObjetoURL de origenDescargado (UTC)SHA-256R2
floorplan_module
#11 · HTTP 200
https://floorplan.medica-tradefair.com/medica2026/Exhibitors/exhibitors_module.js2026-11-15 11:29:5929fce4447dd85490…raw
directory
#71 · HTTP 200
https://www.medica-tradefair.com/vis-api/vis/v1/en/directory/s2026-11-15 11:30:37abc42292c8efae21…raw
profile
#8131 · HTTP 200
https://www.medica-tradefair.com/vis-api/vis/v1/en/exhibitors/medica2026.3081560/slices/profile2026-11-15 11:52:529734a68dbef096c5…raw
contacts
#8135 · HTTP 200
https://www.medica-tradefair.com/vis-api/vis/v1/en/exhibitors/medica2026.3081560/slices/contacts?parentModule=profile&parentModule=stand2026-11-15 11:52:523a0c841e08e0e5ba…raw
products
#8138 · HTTP 200
https://www.medica-tradefair.com/vis-api/vis/v1/en/exhibitors/medica2026.3081560/slices/products2026-11-15 11:52:53be4b9140c01fe16d…raw
appointments
#8142 · HTTP 200
https://www.medica-tradefair.com/vis-api/vis/v1/en/exhibitors/medica2026.3081560/slices/appointments2026-11-15 11:52:536d1df4a3a8326b2a…raw
captura: floorplan_exhibitor
#2033
https://www.medica-tradefair.com/en/Interactive_hall_plan?action=showExhibitor&actionItem=3081560&_event=medica2026#content=infodisplay&fId=12826.12.D54.02026-11-15 11:59:291b27e365a2c2cd03…jpg